The UM 92.1 S studio microphone features our classic M 7 capsule which is renowned for its sound quality. This pressure gradient transducer use two large diameter gold sputtered plastic membranes.
The capsules are selected for optimum polar response.
Three directional characteristics, omni-directional, cardioid and figure-8 are selectable with a pattern selector switch mounted on the power supply.
The vacuum tube microphone shows a considerable signal-to-noise ratio and a high sensitivity. The UM 92.1 S has the typical warm full sound of tube microphones which is especially preferred by singers and soloists.
The direction of maximum sensitivity is radial to the grill, i. e. side addressed.
The vacuum tube amplifier is a time proven design using a pentode working as high µ triode selected for its sonic characteristics.
The UN 920.1 power supply provides the polarization voltage for the capsule and the necessary DC voltages to the microphone amplifier. It is recommended to set the heater voltage of the power supply to 5,8 volts by your service work- shop for cable lengths longer than 50 meters. The UN 920.1 can be powered from AC mains with the primery voltage from 115 or 230 volts - 50 or 60 Hz.
Mounted on the front panel are the pattern selector switch and the on/off - switch. Mounted on the rear panel are the AC mains connector with choise of voltage, the 7-pin Tuchel connector which powers the microphone and a standard 3-pin XLR connector for audio output.

 

high resolution

The microphone UM 92.1 S in Suitcase    L x B x H   450 x 350 x 160 mm
Power supply UN 920.1
Connection cable C 92.1
Elastic suspension EA 92
Windscreen W 92, anthracite
satin nickel
Order-No. 211138
black matt
Order-No. 211139

UM 92.1S, gold, 24 Karat

Popscreen, black
PO 70
Order-No. 600018
Microphone holder, satin nickel
Microphone holder, black matt
MH 80
MH 80
Order-No. 202320
Order-No. 202321
Connection cable
C 92.1 S
Order-No. 202206


Tube-Condenser Microphone
UM 92.1 S
Polar patterns
omni, cardioid, fig-8
Acoustical operating principle
Pressure gradient transducer
Frequency range
40 ... 18000 Hz
Sensitivity at 1 kHz
15 mV / Pa
Rated impedance
200 
Equivalent loudness level
due to inherent noise
CCIR 468-4
25 dB
DIN EN 60651
17 dB - A
Signal-to-noise-ratio
(re. 1 Pa at 1 kHz)
CCIR-weighted
69 dB
A-weighted
77 dB
Max. SPL for THD 0,5 %
120 dB
Total dynamic range of the microphone amplifier
103 dB
DC power supply
120 V -
Anode current
1 mA -
Heater voltage
5,8 V -
Heater current
200 mA -
Tube
EF 86
Output connector
7- pin Tuchel C 70 / A
Weight
430 g
Dimensions (L x )
197 mm x 42 mm

 
Omni

Cardioid

Fig-8

 
Omni
Cardioid Fig-8
125 Hz bis 2 kHz 
 1 / 4 kHz - 8 kHz - 16 kHz
125 / 250 Hz - 500 Hz - 1 kHz - 2 kHz
 1 kHz - 4 kHz - 8 kHz - 16 kHz
125 / 250 Hz - 500 Hz - 1 kHz - 2 kHz