Measuring Equipment Sound / Noise Measuring Microphones MM210

MV210MK250_klMM 210  

1/2" Measurement Microphone
Class 1 DIN EN 60651  
Frequency range 3,5Hz - 20kHz
Free-field
Dynamic range 15dB(A)-135dB
Constant current powered

 

 

The current powered 1/2” Measuring Microphone MM 210 offers facilities for the use of a high-quality electret measuring microphone capsule type MK 250 on multi-channel systems. Typical applications like array arrangements and covered area measuring procedures, e.g. automotive acoustics, can be taken into account.
The measuring microphone is connected to the usual current powered measuring channels such as *ICP® and *Delta Tron® via BNC cable. The microphone holder MH 64 with 1/2” clamp is recommended for mounting. Due to the equality of mechanical construction to conventional 1/2” measuring microphones the 1/2” measuring microphone capsule accessories, e.g. windscreen, nose cone, dehumidifier, etc. can be used. Please check the appropriate data sheets.
The measuring microphone can be calibrated with the Pistonphone type 5002 or other current sound pressure calibrators.
The integrated memory for microphone identification is one of the outstanding features. Microphone data can be entered and read by the manufacturer/user (IEEE P1451.4 TEDS editor).

 

*trade mark: ICP® PCB Piezotronics Inc. / Delta Tron® Brüel & Kjaer

Maintenance and Upkeep

 

In order to maintain its functioning the measurement microphone capsule should be protected against mechanical damage. It should be disconnected from its power source and completely checked for any pollution in regular intervals that have to be defined depending on the operating conditions.
After removal of the protection grid the pollution within the grid and on the diaphragm should be cleaned very carefully with a soft clean cloth or brush.
The measurement microphone capsule is not suitable for use in chemical aggressive conditions and in conductible dust. Condensation must be avoided.

 

 

1/2” Measuring Microphone
MM 210
Microphone Class 1                     21.31- 02.03 PTB-licence no. for official calibration
Transducer type
Capacitive pressure transducer
* Sensitivity
50 mV/Pa
Correction free-field at 1 kHz
0 dB
Random incidence at 1 kHz
0 dB
Principal axis
Microphone axis
* Frequency range free field response
3,5 Hz ... 20 kHz, Class 1 DIN EN 60 651
Polarization voltage
0 V
* Capacitance at 1 kHz
19 pF
Max. SPL for THD 3 % at 1 kHz
135 dB
Output voltage K = 3 %
≥6,5 V eff
Output impedance
< 100Ω
Nom. load impedance
100 kΩ
Current consumption
2 ... 10 mA
nom. 4 mA
Transducer Excitation
UL 24 ... 30 V DC
Time for power up
1 min.
Equivalent loudness level DIN EN 60651
15 dB A
Influence of magnetic field 80 A/m, 50 Hz
< 22 dB
Influence of vibration 1 m/s², 20 Hz ... 1 kHz
60 dB
Operating temperature range < ± 0,5 dB
-25 ... +70 °C
Main ambient temperature coefficient
≤0,01 dB/K
Main ambient pressure coefficient
1 x 10-5 dB/Pa
Influence of relative humidity 30 % to 90 %
< 0,1 dB
Temperature limits
-50 °C … +100 °C
Humidity limits
r. H < 100 %; absence of condensation
Diameter
        with protection grid
13,2 + 0,05 mm
        without protection grid
12,7 + 0,05 mm
Length, including connector
97 mm
Weight
45 g
Preamplifier thread
11,7 mm 60 UNS
Protection grid thread
12,7 mm 60 UNS
Plug
BNC
Microphone identification memory
256-Bit 1-Wire™ EEPROM (DS 2430 AP)
* individually calibrated

 

Frequency Responses

 

freq

 

Measuring microphone MM 210
in wooden case   L x B x H   127 x 87 x 55 mm
Order-No. 318005